Package / Case
20312009101
HARTING

SENSOR CURRENT HALL 2000A AC

  • For Measuring: AC/DC
  • Sensor Type: Hall Effect, Closed Loop
  • Current - Sensing: 2000A
  • Number of Channels: 1
  • Output: Ratiometric, Voltage
  • Sensitivity: -
  • Frequency: -
  • Linearity: ±0.1%
  • Accuracy: ±0.3%
  • Voltage - Supply: 15V
  • Response Time: 1µs
  • Current - Supply (Max): 33mA
  • Operating Temperature: -40°C ~ 85°C
  • Polarization: Bidirectional
  • Mounting Type: Chassis Mount
  • Package / Case: Module, Single Pass Through
Package: Module, Single Pass Through
Stock3,418
Hall Effect, Closed Loop
2000A
1
Ratiometric, Voltage
-
-
±0.1%
±0.3%
15V
1µs
33mA
-40°C ~ 85°C
Bidirectional
Chassis Mount
Module, Single Pass Through
20311009101
HARTING

SENSOR CURRENT HALL 1000A AC

  • For Measuring: AC/DC
  • Sensor Type: Hall Effect, Closed Loop
  • Current - Sensing: 1000A
  • Number of Channels: 1
  • Output: Ratiometric, Voltage
  • Sensitivity: -
  • Frequency: 100kHz
  • Linearity: ±0.1%
  • Accuracy: ±0.4%
  • Voltage - Supply: 15 V ~ 24 V
  • Response Time: 1µs
  • Current - Supply (Max): 28mA
  • Operating Temperature: -40°C ~ 85°C
  • Polarization: Bidirectional
  • Mounting Type: Panel Mount
  • Package / Case: Module, Single Pass Through
Package: Module, Single Pass Through
Stock8,370
Hall Effect, Closed Loop
1000A
1
Ratiometric, Voltage
-
100kHz
±0.1%
±0.4%
15 V ~ 24 V
1µs
28mA
-40°C ~ 85°C
Bidirectional
Panel Mount
Module, Single Pass Through
20310509101
HARTING

SENSOR CURRENT HALL 500A AC

  • For Measuring: AC/DC
  • Sensor Type: Hall Effect, Closed Loop
  • Current - Sensing: 500A
  • Number of Channels: 1
  • Output: Ratiometric, Voltage
  • Sensitivity: -
  • Frequency: -
  • Linearity: ±0.1%
  • Accuracy: ±1%
  • Voltage - Supply: 15 V ~ 24 V
  • Response Time: 1µs
  • Current - Supply (Max): 35mA
  • Operating Temperature: -40°C ~ 85°C
  • Polarization: Bidirectional
  • Mounting Type: Chassis Mount
  • Package / Case: Module, Single Pass Through
Package: Module, Single Pass Through
Stock4,662
Hall Effect, Closed Loop
500A
1
Ratiometric, Voltage
-
-
±0.1%
±1%
15 V ~ 24 V
1µs
35mA
-40°C ~ 85°C
Bidirectional
Chassis Mount
Module, Single Pass Through
20310200101
HARTING

SENSOR CURRENT HALL 200A AC

  • For Measuring: AC/DC
  • Sensor Type: Hall Effect, Closed Loop
  • Current - Sensing: 200A
  • Number of Channels: 1
  • Output: Ratiometric, Voltage
  • Sensitivity: -
  • Frequency: 100kHz
  • Linearity: ±0.1%
  • Accuracy: ±0.8%
  • Voltage - Supply: 15V
  • Response Time: 1µs
  • Current - Supply (Max): 20mA
  • Operating Temperature: -40°C ~ 85°C
  • Polarization: Bidirectional
  • Mounting Type: Chassis Mount
  • Package / Case: Module, Single Pass Through
Package: Module, Single Pass Through
Stock6,570
Hall Effect, Closed Loop
200A
1
Ratiometric, Voltage
-
100kHz
±0.1%
±0.8%
15V
1µs
20mA
-40°C ~ 85°C
Bidirectional
Chassis Mount
Module, Single Pass Through
20310200102
HARTING

SENSOR CURRENT HALL 200A AC

  • For Measuring: AC/DC
  • Sensor Type: Hall Effect, Closed Loop
  • Current - Sensing: 200A
  • Number of Channels: 1
  • Output: Ratiometric, Voltage
  • Sensitivity: -
  • Frequency: 100kHz
  • Linearity: ±0.1%
  • Accuracy: ±0.8%
  • Voltage - Supply: 12 V ~ 15 V
  • Response Time: 1µs
  • Current - Supply (Max): 20mA
  • Operating Temperature: -40°C ~ 85°C
  • Polarization: Bidirectional
  • Mounting Type: Panel Mount
  • Package / Case: Module, Single Pass Through
Package: Module, Single Pass Through
Stock6,012
Hall Effect, Closed Loop
200A
1
Ratiometric, Voltage
-
100kHz
±0.1%
±0.8%
12 V ~ 15 V
1µs
20mA
-40°C ~ 85°C
Bidirectional
Panel Mount
Module, Single Pass Through
20312000101
HARTING

SENSOR CURRENT HALL 2000A AC

  • For Measuring: AC/DC
  • Sensor Type: Hall Effect, Closed Loop
  • Current - Sensing: 2000A
  • Number of Channels: 1
  • Output: Ratiometric, Voltage
  • Sensitivity: -
  • Frequency: 100kHz
  • Linearity: ±0.1%
  • Accuracy: ±0.3%
  • Voltage - Supply: 15 V ~ 24 V
  • Response Time: 1µs
  • Current - Supply (Max): 33mA
  • Operating Temperature: -40°C ~ 85°C
  • Polarization: Bidirectional
  • Mounting Type: Panel Mount
  • Package / Case: Module, Single Pass Through
Package: Module, Single Pass Through
Stock8,910
Hall Effect, Closed Loop
2000A
1
Ratiometric, Voltage
-
100kHz
±0.1%
±0.3%
15 V ~ 24 V
1µs
33mA
-40°C ~ 85°C
Bidirectional
Panel Mount
Module, Single Pass Through
20311000101
HARTING

SENSOR CURRENT HALL 1000A AC

  • For Measuring: AC/DC
  • Sensor Type: Hall Effect, Closed Loop
  • Current - Sensing: 1000A
  • Number of Channels: 1
  • Output: Ratiometric, Voltage
  • Sensitivity: -
  • Frequency: 100kHz
  • Linearity: ±0.1%
  • Accuracy: ±0.4%
  • Voltage - Supply: 15 V ~ 24 V
  • Response Time: 1µs
  • Current - Supply (Max): 28mA
  • Operating Temperature: -40°C ~ 85°C
  • Polarization: Bidirectional
  • Mounting Type: Panel Mount
  • Package / Case: Module, Single Pass Through
Package: Module, Single Pass Through
Stock6,516
Hall Effect, Closed Loop
1000A
1
Ratiometric, Voltage
-
100kHz
±0.1%
±0.4%
15 V ~ 24 V
1µs
28mA
-40°C ~ 85°C
Bidirectional
Panel Mount
Module, Single Pass Through
20310500101
HARTING

SENSOR CURRENT HALL 500A AC

  • For Measuring: AC/DC
  • Sensor Type: Hall Effect, Closed Loop
  • Current - Sensing: 500A
  • Number of Channels: 1
  • Output: Ratiometric, Voltage
  • Sensitivity: -
  • Frequency: 100kHz
  • Linearity: ±0.1%
  • Accuracy: ±0.6%
  • Voltage - Supply: 15 V ~ 24 V
  • Response Time: 1µs
  • Current - Supply (Max): 24mA
  • Operating Temperature: -40°C ~ 85°C
  • Polarization: Bidirectional
  • Mounting Type: Panel Mount
  • Package / Case: Module, Single Pass Through
Package: Module, Single Pass Through
Stock6,084
Hall Effect, Closed Loop
500A
1
Ratiometric, Voltage
-
100kHz
±0.1%
±0.6%
15 V ~ 24 V
1µs
24mA
-40°C ~ 85°C
Bidirectional
Panel Mount
Module, Single Pass Through
20310300101
HARTING

SENSOR CURRENT HALL 300A AC

  • For Measuring: AC/DC
  • Sensor Type: Hall Effect, Closed Loop
  • Current - Sensing: 300A
  • Number of Channels: 1
  • Output: Ratiometric, Voltage
  • Sensitivity: -
  • Frequency: 100kHz
  • Linearity: ±0.1%
  • Accuracy: ±0.5%
  • Voltage - Supply: 15V
  • Response Time: 1µs
  • Current - Supply (Max): 25mA
  • Operating Temperature: -40°C ~ 85°C
  • Polarization: Bidirectional
  • Mounting Type: Panel Mount
  • Package / Case: Module, Single Pass Through
Package: Module, Single Pass Through
Stock7,164
Hall Effect, Closed Loop
300A
1
Ratiometric, Voltage
-
100kHz
±0.1%
±0.5%
15V
1µs
25mA
-40°C ~ 85°C
Bidirectional
Panel Mount