2029-47-SMLF
Bourns Inc.

GAS DISCHARGE TUBE

  • Voltage - DC Spark Over (Nom): -
  • Impulse Discharge Current (8/20µs): -
  • Tolerance: -
  • Number of Poles: -
  • Fail Short: -
  • Mounting Type: -
  • Package / Case: -
Package: -
Stock4,680
-
-
-
-
-
-
2028-42-CFLF
Bourns Inc.

GDT 420V 20% 20KA T/H FAIL SHORT

  • Voltage - DC Spark Over (Nom): 420V
  • Impulse Discharge Current (8/20µs): 20000A (20kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: Yes
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (T-Shape)
Package: Axial Cylinder, 3 Lead (T-Shape)
Stock6,048
20000A (20kA)
±20%
3
Yes
Through Hole
Axial Cylinder, 3 Lead (T-Shape)
2028-35-CFLF
Bourns Inc.

GDT 350V 20% 20KA T/H FAIL SHORT

  • Voltage - DC Spark Over (Nom): 350V
  • Impulse Discharge Current (8/20µs): 20000A (20kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: Yes
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (T-Shape)
Package: Axial Cylinder, 3 Lead (T-Shape)
Stock5,058
20000A (20kA)
±20%
3
Yes
Through Hole
Axial Cylinder, 3 Lead (T-Shape)
2028-25-CFLF
Bourns Inc.

GDT 250V 20% 20KA T/H FAIL SHORT

  • Voltage - DC Spark Over (Nom): 250V
  • Impulse Discharge Current (8/20µs): 20000A (20kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: Yes
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (T-Shape)
Package: Axial Cylinder, 3 Lead (T-Shape)
Stock2,232
20000A (20kA)
±20%
3
Yes
Through Hole
Axial Cylinder, 3 Lead (T-Shape)
2028-23-CFLF
Bourns Inc.

GDT 230V 20% 20KA T/H FAIL SHORT

  • Voltage - DC Spark Over (Nom): 230V
  • Impulse Discharge Current (8/20µs): 20000A (20kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: Yes
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (T-Shape)
Package: Axial Cylinder, 3 Lead (T-Shape)
Stock4,068
20000A (20kA)
±20%
3
Yes
Through Hole
Axial Cylinder, 3 Lead (T-Shape)
2036-09-C2LF
Bourns Inc.

GDT 90V 20% 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 90V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
Package: Axial Cylinder, 3 Lead (Radial Bend)
Stock2,790
10000A (10kA)
±20%
3
No
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)
2030-15T-SM-RPLF
Bourns Inc.

GDT 60V 4KA SURFACE MOUNT

  • Voltage - DC Spark Over (Nom): 60V
  • Impulse Discharge Current (8/20µs): 4000A (4kA)
  • Tolerance: -
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Surface Mount
  • Package / Case: Nonstandard SMD
Package: Nonstandard SMD
Stock7,380
4000A (4kA)
-
3
No
Surface Mount
Nonstandard SMD
2037-60-CLF
Bourns Inc.

GDT 600V 15% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 600V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
Package: Axial Cylinder
Stock3,096
5000A (5kA)
±15%
2
No
Through Hole
Axial Cylinder
2037-40-CLF
Bourns Inc.

GDT 400V 15% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 400V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
Package: Axial Cylinder
Stock6,048
5000A (5kA)
±15%
2
No
Through Hole
Axial Cylinder
2037-35-CLF
Bourns Inc.

GDT 350V 15% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 350V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
Package: Axial Cylinder
Stock6,876
5000A (5kA)
±15%
2
No
Through Hole
Axial Cylinder
2036-60-C3LF
Bourns Inc.

GDT 600V 20% 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 600V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
Package: Axial Cylinder, 3 Lead (Radial Bend)
Stock6,642
10000A (10kA)
±20%
3
No
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)
2036-60-C2LF
Bourns Inc.

GDT 600V 20% 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 600V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
Package: Axial Cylinder, 3 Lead (Radial Bend)
Stock3,780
10000A (10kA)
±20%
3
No
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)
2036-47-C3LF
Bourns Inc.

GDT 470V 20% 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 470V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
Package: Axial Cylinder, 3 Lead (Radial Bend)
Stock7,344
10000A (10kA)
±20%
3
No
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)
2036-47-C2LF
Bourns Inc.

GDT 470V 20% 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 470V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
Package: Axial Cylinder, 3 Lead (Radial Bend)
Stock7,272
10000A (10kA)
±20%
3
No
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)
2036-42-C2LF
Bourns Inc.

GDT 420V 20% 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 420V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
Package: Axial Cylinder, 3 Lead (Radial Bend)
Stock8,568
10000A (10kA)
±20%
3
No
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)
2036-42-C2F
Bourns Inc.

GDT 420V 20% 10KA T/H FAIL SHORT

  • Voltage - DC Spark Over (Nom): 420V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: Yes
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
Package: Axial Cylinder, 3 Lead (Radial Bend)
Stock6,534
10000A (10kA)
±20%
3
Yes
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)
2036-40-C3LF
Bourns Inc.

GDT 400V 20% 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 400V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
Package: Axial Cylinder, 3 Lead (Radial Bend)
Stock7,020
10000A (10kA)
±20%
3
No
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)
2036-40-C2LF
Bourns Inc.

GDT 400V 20% 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 400V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
Package: Axial Cylinder, 3 Lead (Radial Bend)
Stock4,500
10000A (10kA)
±20%
3
No
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)
2036-35-C2FLF
Bourns Inc.

GDT 350V 20% 10KA T/H FAIL SHORT

  • Voltage - DC Spark Over (Nom): 350V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: Yes
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
Package: Axial Cylinder, 3 Lead (Radial Bend)
Stock5,526
10000A (10kA)
±20%
3
Yes
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)
2036-25-C3LF
Bourns Inc.

GDT 250V 20% 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 250V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
Package: Axial Cylinder, 3 Lead (Radial Bend)
Stock2,376
10000A (10kA)
±20%
3
No
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)
2036-25-C3FLF
Bourns Inc.

GDT 250V 20% 10KA T/H FAIL SHORT

  • Voltage - DC Spark Over (Nom): 250V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: Yes
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
Package: Axial Cylinder, 3 Lead (Radial Bend)
Stock2,952
10000A (10kA)
±20%
3
Yes
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)
2036-25-C2FLF
Bourns Inc.

GDT 250V 20% 10KA T/H FAIL SHORT

  • Voltage - DC Spark Over (Nom): 250V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: Yes
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
Package: Axial Cylinder, 3 Lead (Radial Bend)
Stock6,984
10000A (10kA)
±20%
3
Yes
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)
2036-23-C3LF
Bourns Inc.

GDT 230V 20% 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 230V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
Package: Axial Cylinder, 3 Lead (Radial Bend)
Stock6,552
10000A (10kA)
±20%
3
No
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)
2036-23-C2LF
Bourns Inc.

GDT 230V 20% 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 230V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
Package: Axial Cylinder, 3 Lead (Radial Bend)
Stock5,292
10000A (10kA)
±20%
3
No
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)
2036-23-C2FLF
Bourns Inc.

GDT 230V 20% 10KA T/H FAIL SHORT

  • Voltage - DC Spark Over (Nom): 230V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: Yes
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
Package: Axial Cylinder, 3 Lead (Radial Bend)
Stock6,264
10000A (10kA)
±20%
3
Yes
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)
2036-15-CLF
Bourns Inc.

GDT 150V 20% 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 150V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (T-Shape)
Package: Axial Cylinder, 3 Lead (T-Shape)
Stock7,218
10000A (10kA)
±20%
3
No
Through Hole
Axial Cylinder, 3 Lead (T-Shape)
2036-15-C2LF
Bourns Inc.

GDT 150V 20% 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 150V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
Package: Axial Cylinder, 3 Lead (Radial Bend)
Stock7,830
10000A (10kA)
±20%
3
No
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)
2036-9-C3LF
Bourns Inc.

GDT 90V 20% 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 90V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
Package: Axial Cylinder, 3 Lead (Radial Bend)
Stock7,830
10000A (10kA)
±20%
3
No
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)
2036-9-C2LF
Bourns Inc.

GDT 90V 20% 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 90V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
Package: Axial Cylinder, 3 Lead (Radial Bend)
Stock7,056
10000A (10kA)
±20%
3
No
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)
2036-9-C2FLF
Bourns Inc.

GDT 90V 20% 10KA T/H FAIL SHORT

  • Voltage - DC Spark Over (Nom): 90V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: Yes
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
Package: Axial Cylinder, 3 Lead (Radial Bend)
Stock2,286
10000A (10kA)
±20%
3
Yes
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)